High quality dry type transformer supplier

Transformer core cutting machine manufacturer by canwindg.com: Heating of Cables, Motors, and Transformers: Poor power quality can lead to excessive heating in cables, motors, and transformer core cutting machine. This can accelerate the ageing of these components, shorten their lifespan, and potentially lead to catastrophic failures. Maintaining high power quality, including minimizing voltage unbalances, is critical for ensuring the efficient operation of electrical equipment and avoiding the potential negative consequences associated with poor power quality. In conclusion, maintaining high power quality is of paramount importance for the optimal performance and longevity of transformer equipment. High-quality power ensures efficient energy consumption, reduces operational costs, and extends the lifespan of the equipment. It also minimizes the risk of malfunctions, data corruption, and excessive heating of cables, motors, and transformers – issues often associated with poor power quality. Read even more info on https://www.canwindg.com/products-detail-129320.

The cut to length line is a special equipment for the production of transformer core, is our latest generation of cross shear line. This cut to length production line is used for shearing, O punching and V notch of transformer core sheet. The special point of this ctl line is that two O punch and one V notch can work at the same time to produce transformer core pieces with 3, 5, 7 steps in vertical direction and 3, 5, 7 steps in horizontal direction.

Box transformer (usually referred to as “box transformer”) is a compact complete set of power distribution equipment composed of high-voltage power equipment, power transformer, low-voltage electrical equipment and auxiliary equipment. Canwin, a professional box transformer manufacturer & supplier, which focuses on the substation type transformer and traditional box type transformer design in the box shell, A box type transformer is an electronic device that transforms power into alternating current for the purpose of transferring power from one point to another.With small volume, light weight, low noise, low loss, high reliability. Transformer box is widely used in residential areas, commercial centers, light stations, airports, factories and mines, enterprises, hospitals, schools and other places.

Current source inverter has a higher power factor: The current source inverter has a higher power factor, which can achieve higher power factor correction, thereby reducing grid harmonic pollution. However, since a higher power factor requires larger capacitor support, a transformer with a larger capacity needs to be selected to meet the power supply requirements of the capacitor. Current source inverter needs additional power supply: The circuit of current source inverter needs additional power supply to ensure the normal operation of the current loop control. These additional power sources need sufficient capacity to support, so a transformer with a larger capacity needs to be selected to meet the power supply requirements. Therefore, the current source inverter needs a larger transformer capacity to ensure the normal operation of the intermediate inductor, support the power supply of the capacitor and meet the power supply requirements. When selecting a transformer, it needs to be selected according to the actual electrical parameters and performance requirements to ensure the normal operation and stability of the inverter.

Epoxy resin is non – combustible, flame retardant, self – extinguishing solid insulation material, safe and clean. It is also a solid insulation material with proven insulation and heat dissipation technology for more than 40 years.Epoxy resin products can be used for dry type transformer, for insulation parts, for instrument transformer, for electrical composite parts and for room temperature curing. Epoxy resin dry transformer uses epoxy resin as insulation material. The high and low voltage windings are made of copper tape (foil), industrial epoxy resin is poured in vacuum and cured, forming a high strength FRP body structure. Insulation grade F, H. Epoxy resin dry transformer has the characteristics of good electrical performance, strong resistance to lightning impact, strong resistance to short circuit, small size and light weight. Temperature display controller can be installed to display and control the operating temperature of the transformer winding to ensure the normal service life of the transformer.

Independently developed a series of high -speed cut to length line which up to 128 pcs/mins, which increased the cutting speed 2-3 times Independently developed the bridge automatic cutting and automatic lamination cut to length line, which can realize 20 large transformer core column level for automatic lamination, this project has won the record and nomination of Guangdong major research and development projects; Participated in the application and filing of the major science and technology special project of intelligent robot and equipment manufacturing”in the research and development plan of key fields in Guangdong province in 2018-2019. The company has been constantly extending the innovation chain around the guiding ideology of industrial chain deploy innovation chain.

The manufacturing technology and product quality of electrical steel plate is one of the important signs to measure the development level of special steel production and science and technology in a country. At present, the quantity, quality and specification of cold rolled electrical steel in China cannot meet the needs of energy (power) industry development, and there is a big gap between China and Japan in terms of production technology, equipment, management and scientific research.Canwin is one of the most professional silicon steel sheet suppliers in China, which has been specialized in silicon steel manufacturing for over 20 years.Contact us, we are the best choice. Discover extra info at https://www.canwindg.com/

The main pillar of the smart grid is the smart substation, which is not only an important hub for power transmission and distribution, but also directly affects the operational and monitoring capabilities of the smart grid through its operational safety and stability. Through the network, information can be exchanged, and the transformer can share information with the process layer and the station control layer. On the premise of ensuring product performance, the integration of monitoring, control, measurement, protection, and metering is designed to achieve the integration of transformer components with actuators, sensors, and transformers.

Impedance voltage (%): Short-circuit the secondary winding of the transformer and slowly increase the voltage on the primary winding. When the short-circuit current of the secondary winding equals the rated value, the voltage applied on the primary side is the impedance voltage. It is usually expressed as a percentage of the rated voltage. Phase number and frequency: Three-phase is represented by S, and single-phase is represented by D. The frequency f of China’s national standard is 50Hz.There are countries abroad with 60Hz (such as the United States).I. Temperature rise and cooling: The difference between the temperature of the transformer winding or upper oil layer and the temperature of the surrounding environment is called the temperature rise of the winding or upper oil layer. The limit value of the temperature rise of the oil-immersed transformer winding is 65K, and the temperature rise of the oil surface is 55K.There are also various cooling methods: oil-immersed self-cooling, forced air cooling, water cooling, tube type, sheet type, etc.

Why should the iron core of the transformer be grounded? Transformer core grounding is for safety and electromagnetic compatibility considerations. On the one hand, grounding the transformer core prevents contact voltages caused by ground faults, which can pose a shock hazard to humans. Because when a ground fault occurs on one side of the transformer, the iron core on the other side may have a voltage in contact with the earth. If it is not grounded, this voltage cannot be released. On the other hand, grounding the transformer core can also reduce electromagnetic radiation interference, especially for radio equipment and communication systems. This is because the current will generate a magnetic field in the iron core. If the iron core is not grounded, this magnetic field may leak into the surrounding environment and interfere with the normal operation of other equipment. In conclusion, grounding the transformer core is a protective measure against shock hazards and electromagnetic interference.

Canwin electrical equipment manufacturer provides diversified choices for customers. Distribution cabinet, power transformer equipment are available in a wide range of types and styles, in good quality and in reasonable price.Canwin collects scientific and rigorous of manufacturing and quality control management experience, in order to meet the different countries in different fields of capacitor products provide efficient, high-quality, fast service, so that the “Canwin”brand products win a good reputation all over the world.