Best hmi panel provider: Create the external model of the system function design model is mainly to consider the data structure, overall structure and process description of the software, interface design is generally only as an accessory, only the user’s situation (including age, gender, psychological situation, literacy, personality, ethnic background, etc.) have an understanding of the user to design an effective user interface; according to the end user’s hypothesis of the future system (referred to as the system hypothesis) The user model is designed to match the system image (external characteristics of the system) obtained after the system is implemented, so that the user can be satisfied with the system and can use it effectively; the information given by the system hypothesis should be fully considered when building the user model, and the system image must accurately reflect the syntactic and semantic information of the system. In short, only by understanding the user and the task can a good human-machine interface be designed. See extra info on https://www.mochuan-drives.com/products-56168.
Selecting the installation method: The installation mode of plc system is divided into centralized, remote i/o and distributed with multiple plc networking. Centralized hardware does not need to be set to drive remote i/o hardware, the system response is fast and cost is low; Remote I/O type is suitable for large systems, the system device distruibution range is very wide, remote i/o can be scattered installed near the field device, the connection is short, but need to add drivers and remote i/o power supply; The distrbuted network of multiple plc is suitable for the occasions where multiple devices are independently controlled and interconnected, and small plc can be selected, but communication module must be attaced.
Interaction design is subordinate to the product system and is a strong support and refinement to successful product design. If we use the system theory point of view, interaction design is a subsystem of the product design system. Design Principles: The following principles should be considered for the design of human machine interface. The basic user-centered design principle: In the design process of the system, designers should grasp the characteristics of users and discover the needs of users. Users’ opinions should be constantly sought and consulted throughout the development process of the system. The design decisions of the system should be integrated with the users’ work and application environment, and the users’ requirements for the system must be understood. The best way is to involve real users in the development, so that developers can properly understand the needs and goals of users, and the system will be more successful.
Less performance used to match a very high cost, so will it worth? And where is your market point? Maybe more consider another China brand with a very perfect performance too, such as Mochuan brand. Welcome contact us to discuss more. The Second Step: Selecting The HMI Screen Size There are two means of size here. One is screen display screen size, the other is CPU size. Integrating the scale of the entire project, to determine the size of the HMI panel needs, through the project as a whole to present the effect. Do not select the size is too small or too large, becuase too small is look very compact and not enough to operate in well, too large will look the overall proportion of the untuned and waste. It requires engineers to design a good enginnering diagram in advance to allocate the size of each accessory part of the proportion. Wanna win every high value market, it needs to pre-design and seriously selected, but not take for granted. Read extra information at mochuan-drives.com.
Typically, a heartbeat detection is used to define the BOOL, the HMI sets this point at a fixed frequency and the PLC resets when it receives a signal that the point is on. If no signal is received for that point to turn on for a period of time, e.g. 5s, the communication is considered broken. The PLC’s memory clock byte is passed to the touch panel interface, which uses a script to assign the value of this byte to an address in another PLC, which then determines whether the two scan cycles of the returned byte are the same. If so, the communication is interrupted.
Multi-touch capacitive hmi panel is new design and very popular with the market. Why? It is similar the Apple iPone in our life. Becuase its flexible multi touch, very high transmittance, Glass+Glass, anti-scratching, no drifting, IPS full view TFT lcd, high resolution, brightness, high speed and easy flow, supporting animation formats. The color of multitouch HMI is rich and the picture displayed is more delicate. Why many people follows iPhone, just becuase it can bring the users different and beyond imagination experience. Same reasons, why this type panel hmi is very popular in European and American market, just becuase it can bring the project, equipment different experience then to obtain more high value market and to be easily competitive the competitors. Maybe a little try, but to bring a large value, so why not try.
There are lots of temperature control in industry automation. It can select temperature module match the main module plc temperature controller, it also use independent temperature controller to control, both of them are to achieve temperature control. If wanna more flexibility in temperature control, maybe indenpendent temperature module is the first choice. Becuase it can operate without main module plc controller. Mochuan independent plc temperature module integrates an excellent self-tuning algorithm, and user can auto-tune with one button according to needs to accurately obtain PID parameters. Through rs485 communication port, communicate with upper computers of various brands, types of plc, touch screen hmi, configuration software and other upper computers to complete morecomplex logic temperature control.
Selecting HMI screen hardware parameters, mainly look at the CPU running speed and the capacity of the memory. According to the project involves the amount of data exchange animation, the size of the pictures to choose the CPU and memory. When processing more data and picture format is large, needing to choose a fast running speed, memory slightly large HMI. For example, Mochuan 15.6Inch MC-H156E, 7Inch MC-H070CWE, MC-H070CW with 1GHz CortexTM-A7 in CPU. And 10.1Inch MC-H100C, MC-H100CWE with 1GHz cortexTM-A7 and 4GB Flash memory. In addition, also needing to consider the functional requirements needed in the project, such as, how to achieve the multi-level tital pop-up, whether the screen display meets the customer’s need…etc.
Industrial grade fully enclosed embedded industrial hmi touch panel can perfectly cope with all kinds of harsh environment, but also can bring more convenient management services: According to the big data collected by the embedded industrial touch screen plus simple plc, the efficiency of each equipment in the electrical room can be monitored, so that the operation level of the electrical room can be improved and improved based on the evidence.
Industry-sepcific human machine interface may have specific definitions and classifications, such as industrial human machine interface(HMI or simply industrial HMI). Human-Computer Interaction: Human-Computer Interaction, Human-Computer Interaction (HCI, abbreviated HCI, also known as user interface or user interface): is a study of the interaction between a system and its users. Systems can be a variety of machines, or computerized systems and software. The human-computer interaction interface is usually the part that is visible to the user. The user communicates with the system and operates it through the HCI interface. This can be as small as the play button on a radio, or as large as the instrument panel on an airplane, or the control room in a power plant.